Protocol Bridge
Industrial protocols, one tool

Test it. Bridge it. Connect it all.

Protocol Bridge is one lightweight application for industrial communication. It is a protocol tester on your desk, a gateway next to your devices, and the central point that ties many gateways together.

  • IEC 60870-5-104
  • IEC 61850 (MMS)
  • Modbus TCP
  • DNP3
  • OPC UA
  • OPC DA (classic)
  • OPC XML-DA
  • Siemens S7
  • EtherNet/IP (Logix)
  • REST
  • MQTT
One application, three roles

Start with one device. Grow to every site.

The same software works as a tester, as a gateway, or as the central point for many gateways. Pick the role you need today; the configuration you build carries over to the next one.

desktop

Tester

Connect to a device, watch live values, send commands, or simulate the other side. Every protocol in the same window.

edge

Gateway

Runs headless next to your devices and maps data between protocols. A Windows service, a Linux box, or a Docker container on a PLC.

central

Central

Follows many gateways from one place: who is online, live values, commands, configuration deployment, users and an audit log.

Devices connect to Protocol Bridge gateways, gateways connect to Central and to SCADA, MES or cloud systems; a tester connects directly to devices RTU IEC 104 · DNP3 Energy meter Modbus TCP PLC Siemens S7 · EtherNet/IP Protection relay IEC 61850 Tester desktop app on a laptop Gateway · Site A Windows service Gateway · Site B Docker on a PLC Central all sites in one view SCADA · MES · Cloud OPC UA · REST · MQTT IEC 104 · Modbus · … secure, buffered link
One product connects everything: test a single device, convert protocols at a site, or follow every site from one place.
Tester

One interface for every protocol

Stop switching between a different tool for every protocol. Protocol Bridge gives IEC 104, IEC 61850, Modbus, DNP3, OPC UA, classic OPC DA, OPC XML-DA, Siemens S7 and EtherNet/IP the same screens: the same connection editor, the same live data table, the same way to send a command.

  • Act as the client to read a real device, or as the server to simulate one
  • Live values with quality, time stamp, age and a trend for every point, and why a bad one is bad
  • Connection health at a glance: online since, last update, stale data and ongoing errors
  • Send commands and see the device confirm or reject them
  • Troubleshoot step by step: TCP port, protocol start, interrogation, with a hint at the first failure
  • Browse OPC UA, OPC DA and OPC XML-DA servers, or detect the points of IEC 104, DNP3 and IEC 61850 devices and Logix controllers, instead of typing addresses
  • Built-in simulator to try everything without hardware
  • OPC UA security policies and certificate management included
Protocol Bridge points of an IEC 104 connection: an editable table with values, quality, time stamps, age and trends, the explorer on the left and the selected point in the Properties pane
Live data of an IEC 104 connection. IEC 61850, Modbus, DNP3, OPC UA, OPC DA, OPC XML-DA, S7 and EtherNet/IP look and work the same.

See every frame, and what it means

When a device does not answer, the connection check finds the layer that fails: the network, the TCP port, or the protocol itself. The frame trace records the connection and translates every frame field by field, so you do not need a protocol analyser or the standard at hand.

  • Every frame decoded: type, cause of transmission, addresses, values, quality bits, time tags
  • Optional TCP layer: connects, bytes on the wire, who closed the connection and how
  • Hints for known problems, such as a wrong common address, a Modbus register that does not exist, an S7 rack/slot or PUT/GET setting, a Logix route path or slot, a DNP3 link address, an OPC UA security policy or NodeId, an XML-DA item or login, an IEC 61850 selector or report control block in use by another client, or a port that speaks another protocol
  • Device clock checked against arrival time: time zone, drift, clock not synchronised
  • The frames of one command at a click, the IEC 104 server side per SCADA client, and hex from a SCADA log decoded
  • Export for Wireshark, or an AI report: one anonymized file to paste into the assistant of your choice
  • No admin rights and no capture driver needed

IEC 104, IEC 61850, Modbus TCP, Siemens S7, EtherNet/IP, DNP3, OPC UA and OPC XML-DA. How it works

Protocol Bridge frame trace of an IEC 104 connection: the list of frames and the decoded fields of a general interrogation answer
The frame trace of an IEC 104 connection, with the fields of one frame.

From test bench to working gateway

What you build while testing is already the solution. The gateway uses the same editors and the same configuration, so there is nothing to rebuild.

  1. Connect and testAdd the device as a client endpoint and check its values and commands.
  2. Add the targetAdd a server endpoint (OPC UA, IEC 104, Modbus, …) and map points onto it, with scaling and calculations.
  3. Move it to the gatewayTake the same configuration to a gateway. It starts and runs unattended.
The same configuration moves from the desktop tester to a gateway Desktop tester Client · IEC 104 RTU Mapping + calculations Server · OPC UA same config Gateway Client · IEC 104 RTU Mapping + calculations Server · OPC UA runs 24/7, no desktop needed built and verified on your laptop
Gateway

Expose your data the way each system wants it

Read from any supported device and publish the values through REST, MQTT, OPC UA or any other implemented protocol, at the same time. Commands from the consumer side travel back to the device, and the device's answer comes back to the sender.

Devices feed a Protocol Bridge gateway, which maps, converts and calculates, then exposes data through REST, MQTT, OPC UA, IEC 104 and Modbus SOURCES IEC 104 RTUs Modbus meters S7 · Logix PLCs DNP3 · IEC 61850 OPC UA · DA · XML-DA Protocol Bridge Gateway map points between protocols rename addresses · convert types scale and offset custom calculations commands back to the device web UI to configure and watch EXPOSED AS REST API MQTT OPC UA server IEC 104 server Modbus TCP server

Custom calculations

Compute new points from live values with short scripts: totals, averages, deadbands, state logic. Calculated points are mapped and exposed like any device point.

// TotalPower: feeder 1 + 2
p1 + p2

// deadband of 0.5
if !("last" in state)
    || abs(x - state.last) > 0.5 {
    state.last = x;
    x
}

Lightweight and native

The protocol engine is a small native program with a low memory footprint. It runs on an industrial PC, a Linux box, or as a Docker container on a PLC such as the WAGO PFC200, while you open the web interface from another machine.

  • Windows service or Linux, x64 and ARM
  • Starts on boot, restarts after failures
  • Web UI can run on a separate machine

Built for the field

Gateways keep working when the uplink does not.

  • Values are buffered on disk while the central is unreachable
  • Connects out only: no inbound port to open, see how
  • Mutual TLS with certificates issued and renewed by Central
  • Signed configurations, versioned, with one-click rollback
  • Remote commands only where you allow them, every one audited
Protocol Bridge gateway overview in a browser: simulator, IEC 104, OPC UA and Modbus endpoints in one table per role, all online
The gateway's web interface: every endpoint, its state and its points, from any browser.
Security

Connects out. Never lets anyone in.

A gateway sits between the OT network and the outside world, so it is built like a one-way door. It opens every connection to Central itself, from the inside out. Central never connects to a gateway, and no inbound port has to be opened in the plant firewall.

Field devices and local SCADA stay in the OT network. The gateway at the edge opens two outbound connections through the firewall to Central: MQTT 5 with mutual TLS on port 8883 and HTTPS on port 443. Inbound connections from the IT network or the internet are blocked. OT NETWORK · LEVEL 0–2 RTU IEC 60870-5-104 PLC S7 · EtherNet/IP Energy meter Modbus TCP Local SCADA / HMI gateway's OPC UA server field protocols stay inside the OT network EDGE · OT DMZ Gateway opens every link itself own key, never leaves it checks signed configs remote commands off web UI on localhost keeps running and buffers values if the link is down plant firewall IT · DATA CENTRE · CLOUD Central MQTT broker · HTTPS CA · signer · audit log → MQTT 5 · mutual TLS · 8883 → HTTPS · TLS · 443 IT network, internet tries to connect in no inbound port, refused
The gateway is the only conduit between the OT network and the outside. Live values, commands from Central and configuration notices all travel over the connection the gateway opened.

Inside out, by design

Two outbound connections are all a gateway needs: MQTT 5 to the broker and HTTPS to Central. Firewall rules stay short and easy to audit.

  • No inbound port, no VPN, works behind NAT
  • Device protocols never leave the OT network
  • Server endpoints listen only where you configure them

Strong identity, encrypted links

Every gateway proves who it is with its own certificate, issued by Central's certificate authority.

  • TLS 1.2/1.3 with a client certificate per gateway
  • Private key created on the gateway, never copied
  • 90-day certificates, renewed automatically
  • Revoke one and the broker drops it at once

The site keeps the final say

How a gateway is reached, and whether it accepts commands, is set on the gateway only.

  • Configurations signed with Ed25519, older versions refused
  • Remote commands off unless the gateway allows them locally
  • Commands expire after 30 s and are never run twice
  • Passwords stored hashed or encrypted, never in plain text

Supports your NIS2 measures in OT

The NIS2 directive asks operators of essential and important entities, energy, water, manufacturing and more, to manage the cyber risk of their networks, OT included. Protocol Bridge gives you the technical measures for the link between your plants and the rest of the company, and the records to show for them.

The design follows the zones and conduits model of IEC 62443: the OT network is its own zone, and the gateway is the single, documented conduit out of it.

NIS2 obligations rest with the operator, not with a product. Protocol Bridge supports the measures below; it is not a certification. Security details

Cryptography

Art. 21(2)(h). TLS on every link, mutual authentication, signed configurations, secrets encrypted at rest.

Access control

Art. 21(2)(i). Viewer, Engineer, Operator and Admin roles, single sign-on, one identity per gateway.

Incident handling

Art. 21(2)(b). Audit log of every command and deployment, online state of each gateway, instant revocation.

Business continuity

Art. 21(2)(c). Gateways run on when the link fails, buffer values on disk, and roll back to any earlier configuration.

Example setups

From a single laptop to a fleet of sites

A few ways Protocol Bridge is put to work. Pick one to see how it fits together.

Loading the example… open it directly.

Download

Get the Protocol Bridge desktop tester

The desktop app is the tester and a full gateway on your workstation: every protocol, mappings, calculations and the built-in simulator.

Requirements

  • Windows 10 or 11, 64-bit
  • Microsoft Edge WebView2 runtime (preinstalled on current Windows)
  • No hardware needed to start: try the built-in simulator

Quick start

  1. Add a Simulator client and an IEC 104 server on port 2404.
  2. Map simulator * onto the server with forward commands on.
  3. Add an IEC 104 client to 127.0.0.1:2404 and watch the values arrive.

Step by step, with device and gateway examples, in the documentation.

Interested in the gateway or central edition for your sites? Get in touch.